ISO9001, CE
Industry
220V
Chlorine Dioxide
Manual Control
Plywood Box
CPF-50CX
50 grams per hour
Waterman
Made in China
8419200000
20, 000 PCS/Year
Available | Customized Request
Product Description
Chlorine dioxide is ideal for water / wastewater treatment.
Chlorine dioxide generator is a device of on-site producing chlorine dioxide solution.
Waterman brand Chemical Chlorine Dioxide Generator is a water disinfection equipment,
which is on-site producing concentrated chlorine dioxide solution by chemical reaction.
Chemical precursors: Sodium chlorite and hydrochloric acid, or three precursors, option
Place of Origin: Jiangsu, China (Mainland)
Model: CPF-50CX
Certification: ISO9001, CE Marked
EINECS No. 233-162-8
CAS NO. 10049-04-4
Control Mode: Manual / linkage
Installation Method: Wall-mounted or vertical
Power Supply: 220V/50Hz
Detailed Photos
Product Parameters
Main parameters:1. Operating voltage: AC220V plus or minus 10%2. Working temperature: -5 ~ 50 degrees Celsius3. Relative humidity: 80%4. Maximum pressure of water-pipe-line: <0.7Mpa5. There should be no strong electromagnetic field interference around the equipment.6. Function: Manual / Linkage Low liquid level alarm function Timing start / stop function
Alarm remote transfer
Chemical Equation & Raw Material:
5 NaClO2 + 4HCl = 4ClO2 + 5NaCl + 2H2O
NaClO2: industrial sodium chlorite (purity≥78% ) or liquid
Activator: industrial first grade compound hydrochloric acid (purity≥31%) or other weak acid or strong acid
Product Description
Chlorine dioxide is ideal for water / wastewater treatment.
Chlorine dioxide generator is a device of on-site producing chlorine dioxide solution.
Waterman brand Chemical Chlorine Dioxide Generator is a water disinfection equipment,
which is on-site producing concentrated chlorine dioxide solution by chemical reaction.
Chemical precursors: Sodium chlorite and hydrochloric acid, or three precursors, option
Place of Origin: Jiangsu, China (Mainland)
Model: CPF-50CX
Certification: ISO9001, CE Marked
EINECS No. 233-162-8
CAS NO. 10049-04-4
Control Mode: Manual / linkage
Installation Method: Wall-mounted or vertical
Power Supply: 220V/50Hz
Detailed Photos
Product Parameters
Main parameters:1. Operating voltage: AC220V plus or minus 10%2. Working temperature: -5 ~ 50 degrees Celsius3. Relative humidity: 80%4. Maximum pressure of water-pipe-line: <0.7Mpa5. There should be no strong electromagnetic field interference around the equipment.6. Function: Manual / Linkage Low liquid level alarm function Timing start / stop function
Alarm remote transfer
Chemical Equation & Raw Material:
5 NaClO2 + 4HCl = 4ClO2 + 5NaCl + 2H2O
NaClO2: industrial sodium chlorite (purity≥78% ) or liquid
Activator: industrial first grade compound hydrochloric acid (purity≥31%) or other weak acid or strong acid